USB6BX
USB6BX is DATA LINES PROTECTION manufactured by STMicroelectronics.
®
DATA LINES PROTECTION
Application Specific Discretes A.S.D.
APPLICATIONS Where transient overvoltage protection in sensitive equipment is required, such as:
- Universal Serial Bus ports
- RS-423 interfaces
- RS-485 interfaces
- ISDN equipment
- T1/E1 line cards
- HDSL / ASDL interfaces Features n Full diode bridge with integrated clamping protection n Breakdown voltage : VBR = 6V min. n Peak pulse power dissipation : PPP = 500W (8/20µs) n Very low capacitance, patible with high debit data or signal rates. DESCRIPTION In order to prevent fast transients from leading to severe damages in a high speed data system, a specific protection has been developed by STMicroelectronics. The USB6Bx protects the two input lines against overvoltage. Besides, this device also keeps the power rails in a safe limit thanks to the integrated Transil diode. BENEFITS n
SO8
DIL8 n n n
Provides protection for each line and between the supply voltage and GND : 25A , 8/20µs. High ESD protection level : up to level 3 per MIL STD 883C-Method 3015-6 Separated inputs and outputs (so-called 4-point structure) to improve ESD susceptibility. prehensive package pin-out for immediate implementation.
FUNCTIONAL DIAGRAM
PLIES WITH THE FOLLOWING STANDARDS: MIL STD 883C
- Method 3015-6 class 3 C = 100 p F R = 1500 Ω 3 positive strikes and 3 negative strikes (F = 1 Hz) IEC-1000-4-2 level 4 15 k V (air discharge) 8 k V (contact discharge)
TM: ASD and TRANSIL are trademarks of ST Microelectronics.
Vcc I/01 I/02 GND
Vcc I/01 I/02 GND
August 1999 Ed : 5A
1/9
TECHNICAL INFORMATION SURGE PROTECTION The USB6Bx is particularly optimized to perform surge protection based on the rail to rail topology. The clamping voltage VCL can be estimated as follow: VCL+ =Vcc + VF for positive surges for negative surges VCL
- =
- VF with: VF = Vt + rd.Ip (VF forward drop voltage) / (Vt forward drop threshold voltage) Note: the estimations do not take into account phenomena due to parasitic...