Datasheet4U Logo Datasheet4U.com

SKS1200FB6C820V16 - Three-phase controlled bridge rectifier

Key Features

  • P17/130 heatsink.
  • Presspack stack with double side cooling.
  • Forced air cooled Tamb = 35°C per component -40 Type ZU (690V) Size 32 Resistance (80W) Capacitance (900Vdc/ 630Vac) normally closed 3091 0.18 125 800 33 0.47 95 W K/W °C A Ω µF °C Typical.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
www.DataSheet.co.kr SKS 1200F B6C 820 V16 Characteristics Symbol Id Tamb = 35°C Conditions no overload 150 % overload, 60s every 10 min. 200 % overload, 60s every 10 min. min. typ. max. 1200 Unit A A A V V V V kA2s kA2s A/µs V/µs V mA Electrical Data 929 821 1394 1643 1600 DC voltage applied to the capacitor bank network voltage (line side), -20% / +15% 50 Hz / 1 min.