Click to expand full text
Tyco / Electronics
Raychem Circuit Protection 308 Constitution Drive Menlo Park, CA 94025-1164 Phone: 800-227-4856 Fax: 800-227-4866
PolySwitch® PTC Devices
Overcurrent Protection Device
PRODUCT: TR600-160
DOCUMENT: SCD 22470 PCN: 934973 REV LETTER: N REV DATE: MAY 15, 2003 PAGE NO.: 1 OF 1
Specification Status: Released
Max Electrical Rating at 20°C
Operating Voltage: 250VDC Fault Voltage: 600VRMS Interrupt Current: 3ARMS Lead Material: 22 AWG Sn/Pb plated copper Marking:
Raychem Logo and Voltage Part Identification Lot Identification
A
C
F
B
600 160
D E
CENTER TO CENTER
TABLE I. DIMENSIONS:
A mm: in: MIN --MAX 16.0 (0.630) MIN --B MAX 12.6 (0.496) MIN --C MAX MIN 6.0 4.7 (0.236) (0.185) D MAX --E NOM 5.0 (0.197) F MAX 10.0 (0.394)
TABLE II.