3402A
3402A is (3402xA - 3410xA) Three Phase Bridge manufactured by VMI.
..
200 V
- 1,000 V Three Phase Bridge
18.0 A
- 20.0 A Forward Current 70 ns
- 3000 ns Recovery Time
- 3410A 3402FA
- 3410FA 3402UFA
- 3410UFA
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number Working Reverse Voltage (Vrwm) Average Rectified Current @TC (Io) 55°C Volts 3402A 3406A 3410A 3402FA 3406FA 3410FA 3402UFA 3406UFA 3410UFA Amps 100°C Amps Reverse Current @ Vrwm (Ir) 25°C µA 100°C µA 25°C Volts Amps Forward Voltage 1 Cycle Surge Current tp=8.3ms (Ifsm) 25°C Amps Repetitive Surge Current (Ifrm) 25°C Amps Reverse Recovery Time (1) (Trr) 25°C ns °C / W Thermal Impd.
(Vf) u J-C
200 600 1000 200 600 1000 200 600 1000
20.0 20.0 20.0 20.0 20.0 20.0 18.0 18.0 18.0
13.0 13.0 13.0 12.5 12.5 12.5 12.0 12.0 12.0
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
25 25 25 25 25 25 25 25 25
1.2 1.2 1.5 1.5 1.5 1.7 2.0 2.0 2.0
9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0
150 150 150 100 100 100 100 100 100
25 25 25 20 20 20 20 20 20
3000 3000 3000 150 150 150 70 70 70
2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
(1)Trr Testing: If=0.5A, Ir=1.0A, Irr=0.25A
- Op. Temp. & Stg. Temp. = -55°C to +150°C Isolation Voltage: 2000V
.169(4.29) Thru (2 PL) .75 (19.05) .375(9.5)
2.25(57.2) 1.50(38.1)
_
.38(9.7) +
AC AC AC...