Click to expand full text
LPE-5047
Vishay Dale
Surface Mount Transformers/Inductors, Gapped and Ungapped Custom Configurations Available
ELECTRICAL SPECIFICATIONS
(Multiple winds are connected in parallel) Inductance Range: 10µH to 68000µH, measured at 0.10V RMS @ 10kHz without DC current, using an HP 4263A or HP 4284A impedance analyzer. DC Resistance Range: 0.03 ohm to 24.1 ohm, measured at + 25°C ± 5°C. Rated Current Range: 2.29 amps to .07 amps. Dielectric Withstanding Voltage: 500V RMS, 60Hz, 5 seconds.
DIMENSIONS in inches (millimeters)
Pad Layout
STANDARD ELECTRICAL SPECIFICATIONS
MODEL IND. (µH) IND. SCHEMATIC DCR MAX. RATED* SATURATING** MAX. DC CURRENT CURRENT TOL. LETTER (Amps) (Amps) (Ohms)
www.DataSheet4U.com
0.045 [1.14] Pad Dimensions Typical, 10 places 0.079 [2.01]
0.045 [1.14] 0.414 [10.