LPE-6855 - Surface Mount Transformers/Inductors

General Description

TOL.

Series is also availa

Key Features

  • Compliant to RoHS directive 2002/95/EC.

📥 Download Datasheet

Datasheet Details

Part number LPE-6855
Manufacturer Vishay
File Size 98.30 KB
Description Surface Mount Transformers/Inductors
Datasheet download datasheet LPE-6855 Datasheet

Full PDF Text Transcription for LPE-6855 (Reference)

Note: Below is a high-fidelity text extraction (approx. 800 characters) for LPE-6855. For precise diagrams, and layout, please refer to the original PDF.

LPE-6855 Vishay Dale Surface Mount Transformers/Inductors, Gapped and Ungapped, Custom Configurations Available FEATURES • Compliant to RoHS directive 2002/95/EC ELECTRIC...

View more extracted text
s Available FEATURES • Compliant to RoHS directive 2002/95/EC ELECTRICAL SPECIFICATIONS (Multiple winds are connected in parallel) Inductance Range: 10 μH to 150 000 μH, measured at 0.10 VRMS at 10 kHz without DC current, using an HP 4263A or HP 4284A impedance analyzer DC Resistance Range: 0.02  to 46.2 , measured at + 25 °C ± 5 °C Rated Current Range: 3.20 A to 0.17 A Dielectric Withstanding Voltage: 500 VRMS, 60 Hz, 5 s STANDARD ELECTRICAL SPECIFICATIONS MODEL IND. (μH) IND. SCHEMATIC DCR MAX. MAX. RATED DC CURRENT TOL. LETTER () (A) (1) SATURATING CURRENT (A) (2) LPE6855ER151NU 150 ± 30 % A 0.28 0.84 N/A LPE6855ER22