Datasheet4U Logo Datasheet4U.com

AFE5809 - 8-Channel Ultrasound Analog Front-End

General Description

The AFE5809 device is a highly-integrated analog front-end (AFE) solution specifically designed for ultrasound systems in which high performance and small size are required.

The AFE5809 device integrates a complete time-gain-control (TGC) imaging path and a CWD path.

Key Features

  • 1 8-Channel Complete Analog Front-End.
  • LNA, VCAT, PGA, LPF, ADC, and CW Mixer.
  • Programmable Gain Low-Noise Amplifier (LNA).
  • 24-, 18-, 12-dB Gain.
  • 0.25-, 0.5-, 1-VPP Linear Input Range.
  • 0.63-, 0.7-, 0.9-nV/rtHz Input Referred Noise.
  • Programmable Active Termination.
  • 40-dB Low-Noise Voltage Controlled Attenuator (VCAT).
  • 24-/30-dB Programmable Gain Amplifier (PGA).
  • Third-Order Linear Phase Low-Pass Filter (LPF).

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Product Folder Sample & Buy Technical Documents Tools & Software Support & Community AFE5809 SLOS738E – SEPTEMBER 2012 – REVISED AUGUST 2015 AFE5809 Fully Integrated, 8-Channel Ultrasound Analog Front End With Passive CW Mixer, and Digital I/Q Demodulator, 0.75 nV/rtHz, 14, 12-Bit, 65 MSPS, 158 mW/CH 1 Features •1 8-Channel Complete Analog Front-End – LNA, VCAT, PGA, LPF, ADC, and CW Mixer • Programmable Gain Low-Noise Amplifier (LNA) – 24-, 18-, 12-dB Gain – 0.25-, 0.5-, 1-VPP Linear Input Range – 0.63-, 0.7-, 0.