LM5056A Description

The LM5056/LM5056A bines high-performance analog and digital technology with a PMBus™ pliant SMBus™ and I2C interface to accurately measure the electrical operating conditions of systems connected to a backplane power bus. The LM5056/LM5056A continuously supplies real-time power, voltage, current, temperature and fault data to the system management host via the SMBus interface. The LM5056/LM5056A monitoring block...

LM5056A Key Features

  • 2 Input Voltage Range: 10 V to 80 V
  • Real-Time Monitoring of VIN, IIN, PIN, VOUT, and VAUX with 12-bit resolution, 1-kHz sampling rate
  • True input Power Measurement using simultaneous sampling of Vin and Iin
  • Remote Temperature Sensing with programmable warning thresholds
  • Power Measurement Accuracy
  • LM5056A: ±1.75%
  • LM5056: ±2.25%
  • Current Measurement Accuracy
  • LM5056A: ±1.25%
  • LM5056: ±1.5%