Datasheet Summary
Low-ohmic single-pole single-throw analog switch
Rev. 01
- 14 September 2009 Product data sheet
1. General description
The NX3L1T66 provides one single-pole single-throw analog switch function. It has two input/output terminals (Y and Z) and an active HIGH enable input pin (E). When E is LOW, the analog switch is turned off. Schmitt-trigger action at the enable input (E) makes the circuit tolerant to slower input rise and fall times across the entire VCC range from 1.4 V to 4.3 V. A low input voltage threshold allows pin E to be driven by lower level logic signals without a significant increase in supply current ICC. This makes it possible for the NX3L1T66 to switch 4.3 V signals...