M29W160FB Overview
6 2 Signal descriptions . 12 2.1 Address inputs (A0-Amax) . 12 2.2 Data inputs/outputs (DQ0-DQ7).
M29W160FB Key Features
- Supply voltage
- VCC = 2.5 V to 3.6 V (access time: 80 ns) or 2.7 to 3.6 V (access time: 70 ns) for Program, Erase and Read
- VPP = 12 V for Fast Program (optional, available in the M29W320FT/B only)
- Access time: 70, 80 ns
- Programming time
- 10 μs per byte/word typical
- Memory organization
- M29W160FT/B: 35 blocks including 1 boot block (top or bottom location), 2 parameter blocks and 32 main blocks
- M29W320FT: 67 blocks including 1 boot block (top or bottom location), 2 parameter blocks and 64 main blocks
- Program/Erase controller