TCST110
Overview
This device has a compact construction where the emitting-light sources and the detectors are located face-to-face on the same optical axis. The operating wavelength is 950 nm.
- Compact construction
- No setting efforts
- Polycarbonate case protected against ambient light 95 10796 + *
- 2 case variations
- 3 different apertures
- CTR selected in groups (regarding fourth number of type designation) E 7.6 0.3” + Top view Order Instruction Ordering Code TCST1103A) TCST2103B) TCST1202A) TCST2202B) TCST1300A) TCST2300B) Resolution (mm) / Aperture (mm) 0.6 / 1.0 0.4 0.2 / / 0.5 0.25 Remarks No mounting flags With two mounting flags No mounting flags With two mounting flags No mounting flags With two mounting flags Document Number 83764 Rev. A5, 08-Jun-99 1 (9) TCST110. up to TCST230. Vishay Telefunken Absolute Maximum Ratings Input (Emitter) Parameter Reverse voltage Forward current Forward surge current Power dissipation Junction temperature Test Conditions Symbol VR IF IFSM PV Tj Value 6 60 3 100 100 Unit V mA A mW °C tp ≤ 10 ms Tamb ≤ 25°C Output (Detector) Parameter Collector emitter voltage Emitter collector voltage Collector current Collector peak current Power dissipation Junction temperature Test Conditions Symbol VCEO VECO IC ICM PV Tj Value 70 7 100 200 150 100 Unit V V mA mA mW °C tp/T = 0.5, tp ≤ 10 ms Tamb ≤ 25°C Coupler Parameter Total power dissipation Operating temperature range Storage temperature range Soldering temperature Test Conditions Tamb ≤ 25°C Symbol Ptot Tamb Tstg Tsd Value 250 -55 to +85 -55 to +100 260 Unit mW °C °C °C 2 mm from case, t ≤ 5 s 2 (9) Document Number 83764 Rev. A5, 08-Jun-99 TCST110. up to TCST230. Vis