Description
MIN NOM MAX UNITS
Input Voltage - AC Input Frequency Hold-up Time Input Protection Inrush Surge Current Operating Frequency
Continuous input range.85 47 20
264 63
VAC Hz ms A kHz
Non-user serviceable, internally-located input line fuse.Internally limited by thermistor and electronic switch.Switching frequency of main output transformer.125
30 145
CompactPCI and PICMG are registered trademarks of the PCI Industrial Computer Manufacturers Group.REV.10/25/01
1
CPA SERIES - 250 WATT
Features
- Wide Input Range (85-264 VAC).
- Delivers 40A for the +5V and +3.3V Outputs (No Restrictions).
- Single-wire Current Share on Outputs V1, V2, and V3.
- Remote Sense on Outputs V1, V2, and V3.
- Overtemperature, Overvoltage, and Overcurrent Protection.
- Input Good and Power Fail LED Indicators.
- Power Fail and Temperature Warning Signals.
- Inhibit and Enable Inputs.
- Fully Compliant to PICMG® 2.11 CompactPCI® Specification.