Advanced Power Technology APT1001R1AVR
MOSFET
MAXIMUM RATINGS
Symbol VDSS ID IDM VGS VGSM PD TJ,TSTG TL IAR EAR EAS Parameter Drain-Source Voltage Continuous Drain Current @ TC = 25°C Pulsed Drain Current 1 All Ratings: TC = 25°C unless otherwise specified. APT1001R1AVR UNIT Volts Amps 1000 9 36 ±30 ±40 200 1.6 -55 to 150 300 9 30 4 Gate-Source Voltage Continuous Gate-Source Voltage Transient Total Power Dissipation @ TC = 25°C Linear Derating Factor Operating and Storage Junction Temperature Range Lead Temperature: 0.063" from Case for 10 Sec. Avalanche Current 1 Volts Watts W/°C °C Amps mJ (Repetitive and Non-Repetitive) 1 Repetitive Avalanche Energy Single Pulse Avalanche Energy 1210 STATICELECTRICAL CHARACTERISTICS
Symbol BVDSS ID(on) RDS(on) IDSS IGSS VGS(th) Characteristic / Test Conditions Drain-Source Breakdown Voltage (VGS = 0V, ID = 250µA) On State Drain Current 2 MIN TYP MAX UNIT Volts Amps 1000 9 1.100 25 250 ±100 2 4 (VDS > I D(on) x R DS(on) Max, VGS = 10V) 2 Drain-Source On-State Resistance (VGS = 10V, 0.5 ID[Cont.