Datasheet4U Logo Datasheet4U.com

LTC6812-1 - 15 Cell Battery Stack Monitor

📥 Download Datasheet

Preview of LTC6812-1 PDF
datasheet Preview Page 2 datasheet Preview Page 3

LTC6812-1 Product details

Description

n Measures Up to 15 Battery Cells in Series n 2.2mV Maximum Total Measurement Error n Stackable Architecture for High Voltage Systems n Built-In isoSPI™ Interface n 1Mb Isolated Serial Communications n Uses a Single Twisted Pair, Up to 100 Meters n Low EMI Susceptibility and Emissions n Bidirectional for Broken Wire Protection n 245µs to Measure All Cells in a System n Synchronized Voltage and Current Measurement n 16-Bit Delta-Sigma ADC with Programmable Noise Filter n Engineered for ISO 26262

📁 LTC6812-1 Similar Datasheet

  • LTC6800 - Instrumentation Amplifier (Linear Technology)
  • LTC6801 - Independent Multicell Battery Stack Fault Monitor (Linear Technology)
  • LTC6802-1 - Multicell Battery Stack Monitor (Linear Technology)
  • LTC6802-2 - Multicell Addressable Battery Stack Monitor (Linear Technology)
  • LTC6803-1 - Multicell Battery Stack Monitor (Linear Technology)
  • LTC6803-2 - Multicell Battery Stack Monitor (Linear Technology)
  • LTC6803-3 - Multicell Battery Stack Monitor (Linear Technology)
  • LTC6803-4 - Multicell Battery Stack Monitor (Linear Technology)