TPN3021
Tripolar overvoltage protection for network interfaces
Features
■ Triple crowbar protection
■ Low capacitance
■ Low holding current: IH = 30 mA minimum ■ Surge current:
IPP = 200 A, 2/10 µs IPP = 30 A, 10/1000 µs
Benefits
■ Trisil™ technology is not subject to ageing and provides a fail safe mode in short circuit for a better protection.
■ This device can be used to help equipment to meet main standards such as UL1950, IEC 950 / CSA C22.2 and UL1459.
■ Trisils have UL94 V0 approved resin.
■ SO8 package is JEDEC registered.
■ Trisils comply with the following standards GR-1089 Core, ITU-T-K20/K21, VDE0433, VDE0878, IEC 61000-4-2.
Applications
Dedicated to data line protection, this device provides a tripolar protection function.